Accolade’s FPGA-accelerated Flow Shunting feature speeds packets through 10, 40, and 100GE data center networks

2017年11月8日 | By News | Filed in: News.

http://ift.tt/2heRnk8

 

Accolade’s new Flow-Shunting feature for its FPGA-based ANIC network adapters lets you more efficiently drive packet traffic through existing 10/40/100GE data center networks by offloading host servers. It does this by eliminating the processing and/or storage of unwanted traffic flows, as identified by the properly configured Xilinx UltraScale FPGA on the ANIC adapter. By offloading servers and reducing storage requirements, flow shunting can deliver operational cost savings throughout the data center.

 

The new Flow Shunting feature is a subset of the existing Flow Classification capabilities built into the FPGA-based Advanced Packet Processor in the company’s ANIC network adapters. (The company has written a technology brief explaining the capability.) Here’s a simplified diagram of what’s happening inside of the ANIC adapter:

 

 

Accolade Flow Shunting.jpg 

 

 

The Advanced Packet Processor in each ANIC adapter performs a series of packet processing functions including flow classification (outlined in red). The flow classifier inspects each packet, determines whether each packet is part of a new flow or an existing flow, and then updates the associated lockup table (LUT)—which resides in a DRAM bank—with the flow classification. The LUT has room to store as many as 32 million unique IP flow entries. Each flow entry includes standard packet-header information (source/destination IP, protocol, etc.) along with flow metadata including total packet count, byte count, and the last time a packet was seen. The same flow entry tracks information about both flow directions to maintain a bi-directional context. With this information, the ANIC adapter can take specific actions on an individual flow. Actions might include forwarding, dropping, or re-directing packets in each flow.

 

These operations form the basis for flow shunting, which permits each application to decide from which flow(s) it does and does not want to receive data traffic. Intelligent, classification-based flow shunting allows an application to greatly reduce the amount of data it must analyze or handle, which frees up server CPU resources for more pressing tasks.

 

 

For more information about Accloade’s UltraScale-based ANIC network adapters, see “Accolade 3rd-gen, dual-port, 100G PCIe Packet Capture Adapter employs UltraScale FPGAs to classify 32M unique flows at once.

 

 